Sterilizer

The MOST-L Laboratory Series Steam Sterilizers are mainly applied by laboratories in universities, pharmaceutical factories, inspection departments and disease control & prevention centers for sterilization of labware, culture medium, unsealed liquid or preparation and materials that may contact blood or body fluid in scientific research or medical care units. 

1 (1)

Characteristics

Clamshell-type Automatic Door Structure

The multipoint synchronously Interaction and pressing technology renders more reliable door sealing, and the one-button door opening saves time and energy.

Humanized Operation System

Microcomputer automatic control, LCD text display and induction-type buttons facilitates observation of informational parameters of equipment and process messages of sterilization, making the operation simple and convenient. 

Water Quality Testing Function

The system examines water quality within the tank, and would prompt the user in case the water quality becomes off-spec. 

Rich Program Types

108 programs in three categories (lab program, medical program and custom program) are set so that the user may flexibly have the program parameters defined. 

Flexible Steam-discharge Control

The user may, based on actual demand, change parameters to control the steam-discharge velocity, which includes rapid, slow and zero. 

No Steam Exhaust throughout the Whole Process

The equipment water is stored to achieve internal circulation of water steam. A condensing system is mounted inside to guarantee that no steam is exhausted throughout the whole process, effectively avoiding aerosol generation and lab injury occurrence and thus ensuring the safety. 

Safety Interlocking

Automatic protection device against overtemperature: the heating power supply would be automatically cut off and trigger the alarm in case of overtemperature. 

1 (3)1 (4)1 (2)

Dry burning-resistant protection device: the heating power supply would be automatically cut off and trigger the alarm in case the water level is lower than the set water level system. 

Door safety interlocking device: an electronic lock structure is adopted, and the sterilization process can only be initiated after the door is fully locked; the door would not open if any pressure exists inside the inner chamber or the power supply is not connected. 

Automatic pressure-relieving device against overpressure: the safety valve would automatically relieve the pressure in case the pressure inside the inner chamber reaches the opening pressure of safety valve. 

Electronic circuit protection device: the AC major loop is with safety protection, and the quality-control loop is with overvoltage and overload protection.  

Cooling lock: the door would not open in the event that the temperature of liquid inside the inner chamber exceeds the safety limit, avoiding dangers that may be caused by liquid splash or even bottle explosion and thus guaranteeing safety of operators and materials. 

1 (1)

Optional Functions

Dual-temperature Control System

It would effectively and accurately control the temperature of inner chamber while guarantee the uniformity and accuracy of inner and outer load temperatures if the mobile probe that may test the load temperature for dual-temperature control is selected. 

Drying System

The rear thermal-drying system is adopted to effectively dry the materials. 

Enclosed Liquid Sterilization Function

Hardware configuration and software control are added to realize sterilization of enclosed liquid without bottle explosion or bag expansion. 

Rapid Cooling Function

The rapid cooling system is selected to effectively reduce 80% of cooling time, substantially enhancing equipment efficiency. 

Data Recording

Mini-printer: thermal printing without noise, used to print process parameters like date, time and temperature, etc. 

Electronic storage: U-disk storage function, with special software system to analyze data. 

Remote monitoring: with tablet PC to achieve remote monitoring of equipment. 

1 (6)1 (8)

The manual sliding door structure is employed, and the sealing door is equipped with insulation device. The stainless-steel cover resists corrosion and is easy for cleaning. 

Need more Information?
Brochure
Download the brochure to learn more about this product.
Need Help Choosing?
Ready to place your order? We are here to assist you with any questions you may have.