Washer Disinfector

YXQG03B High-end Autoclave

Application

YXQG Series stainless steel Portable Autoclave is a kind of sterilization equipment with pressure steam as medium. It is used for sterilizingsurgical instruments, beddings and glassware of medical units.

1 (3)

Features

Adopt microcomputer control, touch key.

Dynamic display of sterilization process, LED digital display of chamber temperature, time and fault code alarm.

Manual water filling and drainage, automatic control of temperature heating, sterilization and steam venting.

The default parameters can be set and modified by users, the counts of positive pressure pulses, sterilization temperature, sterilization time, boiling point temperature and other parameters can be set by users.

Temperature sensor control, precise control of sterilization chamber temperature.

Automatic over-temperature protection device, door safety interlock device, safety valve for automatic pressure relief, short-circuit protection, over-pressure protection.

Safety Protection Device

Anti-dry burning device: when the water level is lower than the specified level, it can automatically cut off the heating power.

Automatic steam venting device: when the pressure exceeds the set value, the steam release valve will automatically open and discharge steam to keep the sterilization pressure in the chamber.

Over-pressure protection device: automatic pressure relief safety valve will open automatically to release pressure when the pressure exceeds the safety value.

Door safety interlock device: If the door is not closed, the chamber cannot be pressurized, and if there is pressure in the chamber,the door cannot be opened.

Electronic circuit safety device: AC main circuit with fuse.

YXQG02B Electric Heating Autoclave

Application

YXQG Series stainless Steel Portable Autoclave is a kind of sterilization equipment using pressure steam as medium. It is used for sterilizing surgical instruments, beddings and glassware of medical units.

1 (1)

Features

Fast-opening structure with cog connection, the lid is sealed by horizontal rotating engagement with the autoclave body,convenient and quick operation

Equipped with tiny venting holes, so that a small amount of steam is always discharged during the sterilization process to ensure the uniformity of sterilization temperature and the saturation of steam

Steam release valve is provided to discharge the cold air inside the Autoclave to ensure the saturation of steam and to release the pressure inside the chamber after sterilization.

Double-scale pressure gauge to view the pressure and temperature inside the Autoclave

Adopt immersion type stainless steel electric heating tube, with long service life

Manual water injection and manual steam venting


Technical Parameters

Working pressure: 0.142Mpa

Max working temperature: 126°C

Chamber Material: 304 Stainless steel

 image.png

*Voltage and frequency of some Model can be customized according to user demands. The actual voltage and frequency of the equipment /s subject to the actual order.


Technical Parameters

Working pressure: 0.142Mpa

Max working temperature: 126°C

Chamber Material: 304 Stainless steelimage.png